Maintenance Guidelines for Electric Power Tools

Aug 10, 2026

Leave a message

1. Use No. 20 machine oil for the oil pump.
2. The oil level must be maintained within the range visible through the oil sight glass.
3. When adding or changing oil, the oil must be filtered through a mesh of 80 mesh or finer; the oil tank must be cleaned thoroughly during oil changes. The oil change interval is six months.
4. The operating oil temperature range is 10°C to 50°C.
5. Before starting the electric pump, open the air vent nut and set the switch to the "unload" (bypass) position.
6. If the motor temperature becomes excessively high during operation, stop using the pump immediately and allow it to cool down before resuming use.
7. The pump is factory-adjusted; do not alter settings arbitrarily. Any readjustment must be performed using a pressure gauge.
8. High-pressure oil hoses undergo 105 MPa testing before leaving the factory. However, as rubber hoses are prone to aging, users must inspect them regularly-every six months for standard use, or every three months for frequent use. Inspections should involve pressure testing at 87.5 MPa; do not use the hose if there are signs of damage, bulging, or leakage.
9. Bearings should generally be cleaned every six months; apply fresh grease during reassembly.

Send Inquiry